三体位动态超声在新生儿PICC置管尖端定位中的应用
作者:
作者单位:

作者简介:

女,本科,主管护师,护士长

通讯作者:

基金项目:


Application of three-position dynamic ultrasound for catheter tip localization du-ring PICC placement in neonates
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    目的 观察三体位动态超声与单一体位静态超声在新生儿PICC尖端精准定位的临床效果。方法 采用基于时间段的前瞻性比较研究设计,将新生儿重症病房收治的128例行PICC置管的新生儿作为研究对象,按照置管时间段先后顺序分为两组各64例。对照组置管过程中采用单一体位(即功能位)床旁超声进行静态导管尖端评估及定位;干预组则采用三体位(内收体位、功能位、外展体位)床旁超声进行动态导管尖端评估,调整导管尖端位置,直至确定最佳定位。结果 干预组PICC原发性异位发生率7.81%,显著低于对照组的21.88%(P<0.05);干预组X线暴露次数、调管次数显著少于对照组(均P<0.05)。结论 三体位动态超声监测可实现新生儿PICC置管尖端的动态、精准定位,有效降低导管异位,减少X线暴露,提升新生儿PICC置管及护理的安全性。

    Abstract:

    Objective To compare the clinical effectiveness of three-position dynamic ultrasound with single-position static ultrasound for accurate catheter tip localization during peripherally inserted central catheter (PICC) placement in neonates. Methods A prospective comparative study with a time-sequence design was conducted. A total of 128 neonates admitted to the neonatal intensive care unit who underwent PICC placement were consecutively enrolled and allocated into two groups according to the chronological period of catheter insertion, with 64 participants in each group. In the control group, bedside ultrasound with a single position (functional position) was used for static assessment and localization of the catheter tip during PICC placement. In the intervention group, three-position bedside ultrasound (adduction position, functional position, and abduction position) was used to dynamically assess the catheter tip, and the catheter tip position was adjusted until the optimal location was achieved. Results The incidence of primary catheter malposition in the intervention group (7.81%) was significantly lower than that in the control group (21.88%, P<0.05). In addition, the intervention group had significantly fewer radiographic examinations, and catheter repositioning procedures than the control group (all P<0.05). Conclusion Three-position dynamic ultrasound enabled dynamic and precise localization of the PICC catheter tip in neonates, effectively reducing catheter malposition and related complications. It also decreased radiation exposure, and improved the safety of PICC placement and nursing care in neonates.

    参考文献
    相似文献
    引证文献
引用本文

付芳,黄海珊,廖淑芳,易琼.三体位动态超声在新生儿PICC置管尖端定位中的应用[J].护理学杂志,2026,41(18):67-70,81

复制
文章指标
  • 点击次数:
  • 下载次数:
历史
  • 收稿日期:2026-05-09
  • 最后修改日期:2026-07-01
  • 录用日期:
  • 在线发布日期: 2026-10-23